All products of Wuxi ZOZEN Boiler Co., Ltd. are 100% factory inspected to ensure high quality. We have manufactured 6 series of 400 types of boilers, including steam boilers, hot water boilers, power station boilers, fire tube boilers, water tube boilers, CFB boilers, chain grate boilers, biomass fuel boilers, gas and oil boilers and waste heat Recovery boilers, products are widely used in manufacturing (chemical, coking, paper, food processing, etc.), thermal power plants, building materials and other industries.

Recommend Products

gas/oil fired boiler

1-20 t/h | 0.7-2 Mpa

biomass steam boiler

2 – 20 t/h | 1 - 2.5 Mpa

thermal oil heater

700 - 14000 KW

CFB steam boiler

35 - 75 t/h | 1.25 - 5.3 Mpa

Related Cases

Coal-fired Boiler

6tph SZL series boiler project

Location: Bangladesh

Equipment: SZL6-1.25-AII

Coal-fired Boiler

4 tph DZL series boiler Project

Location: Central Java, Indonesia

Equipment: DZL4-1.25-AII

Biomass-fired Boiler

20 tph SZL series boiler project

Location: Thailand

Equipment: SZL20-2.45-M

steam heating mechanism | tlv - a steam specialist company .

Steam Heating Mechanism | TLV - A Steam Specialist Company .

Evaluating heat transfer in a heat exchanger therefore requires the overall heat transfer coefficient (i.e. U-value), which takes into account all three mechanisms. Its …

Get a Quote
overall heat transfer coefficient | tlv - a steam .

Overall Heat Transfer Coefficient | TLV - A Steam .

The overall heat transfer coefficient is influenced by the thickness and thermal conductivity of the mediums through which heat is transferred. The larger the coefficient, the easier heat is transferred from its source to the product being heated.

Get a Quote
boiler efficiency guide - cleaver-broo

BOILER EFFICIENCY GUIDE - Cleaver-Broo

will yield a higher overall heat-transfer coefficient. In an attempt to improve heat transfer, many boilers with fewer passes will employ after-the-fact add-on devices within the tubes, or will be tested at less than full firing rate to prove lower stack temperatures. Don’t be fooled. Turbulators and similar add on devices may help pass

Get a Quote
heat transfer | physics foru

Heat transfer | Physics Foru

May 06, 2017· The latent heat of vaporisation of the water at 180ºC is 2015 kJ kg–1. Feed water temperature = 180ºC. Determine the amount of steam produced per hour, if the total heat loss is 10% of the heat available for steam raising. (b) The overall heat transfer coefficient based on the outside area of the tubes is given as 54 W m–2 K–1.

Get a Quote
convective heat transfer coefficients table chart .

Convective Heat Transfer Coefficients Table Chart .

Condensers heat transfer coefficients. Cold Fluid : Hot Fluid : Overall U (BTU/hr-ft 2-F) Water : Steam (pressure) 350 -750 : Water : Steam (vacuum) 300 – 600 : Water or brine : Organic solvent (saturated, atmospheric) 100 – 200 : Water or brine : Organic solvent ( atmospheric, high non-condensables) 20 – 80 : Water or brine : Organic ...

Get a Quote
finned tube - an overview | sciencedirect topi

Finned Tube - an overview | ScienceDirect Topi

Calculation of the overall heat transfer coefficient U o based on the finned outer surface area A o considering the fouling factors r o and r i 255. 12.3.6. Calculation of the overall heat transfer coefficient U i for the inner tube surface area A i considering the fouling factors r o and r i 256. 12.3.7. Fouling and Temperature Gradient 256 ...

Get a Quote
jacketed vessel heat transf

Jacketed Vessel Heat Transf

Jacketed Vessel Heat Transfer Calculation estimates overall heat transfer coefficient for a vessel with an agitator along with heating/cooling medium flowing in jacket, spiral jacket or half pipe coil.

Get a Quote
what is overall heat transfer coefficient - u-factor .

What is Overall Heat Transfer Coefficient - U-factor .

The overall heat transfer coefficient is related to the total thermal resistance and depends on the geometry of the problem. For example, heat transfer in a steam generator involves convection from the bulk of the reactor coolant to the steam generator inner tube surface, conduction through the tube wall, and convection (boiling) from the outer tube surface to the secondary side fluid.

Get a Quote
solved: question 1: waste-water heat recovery analysis a c .

Solved: Question 1: Waste-water Heat Recovery Analysis A C .

The overall heat transfer coefficient is U = 1200W/m2; the surface area of the thin walled tubes is 20m2 and the flowrate of the discarded water from the laundry is also 3kg/sec. ORIGINAL SETUP water into laundry water supply 3kg/sec 120 water discarded to sewer 3kg/sec 70C 7540 gas boiler WASTE WATER RECOVERY SETUP water discarded from Laundry ...

Get a Quote
what is heat exchanger - heat transfer coefficient - u .

What is Heat Exchanger - Heat Transfer Coefficient - U .

The overall heat transfer coefficient, U, is related to the total thermal resistance and depends on the geometry of the problem. For example, heat transfer in a steam generator involves convection from the bulk of the reactor coolant to the steam generator inner tube surface, conduction through the tube wall, and convection (boiling) from the outer tube surface to the secondary side fluid.

Get a Quote
overall heat transfer co-efficient calculation - pharma .

Overall Heat Transfer Co-Efficient Calculation - Pharma .

Overall Heat Transfer Co-efficient is the combination of the possible Individual Heat Transfer Co-efficient, which are due to the following Heat Transfer modes, 1. Rate of convective heat transfer from Fluid to Medium Wall, and 2. Conductive Heat Transfer from Medium Walls one end to other end, 3. Convective Heat Transfer from Medium wall to ...

Get a Quote
heat transfer | spirax sar

Heat Transfer | Spirax Sar

The over all heat transfer coefficient (U) This takes into account both conductive and convective resistance between two fluids separated by a solid wall. The overall heat transfer coefficient is the reciprocal of the overall resistance to heat transfer, which is the sum of the individual resistances.

Get a Quote
overall heat transfer coefficient for shell and tube heat .

Overall heat transfer coefficient for shell and tube heat .

Sep 17, 2017· Fundamental Concepts of Overall Heat Transfer Coefficient (OHTC) In shell and tube type heat exchanges overall heat transfer coefficient (OHTC ) is product of the three factors mainly. They are Tube inside liquid media film coefficient , Shell side heating media film coefficient and metal wall resistance.. Heat transfer is the science which deals with the rates of exchanges of heat …

Get a Quote
overall heat transfer coefficient in d type boile

overall heat transfer coefficient in d type boile

overall heat transfer coefficient in d type boilers Related Information Design & Analysis of Shell & Tube Type Heat … and tube heat exchanger is the most common heat exchanger type; therefore the study of its design and analysis is of great importance for conserving energy in heat exchange process.

Get a Quote
submerged coils - heat transfer coefficien

Submerged Coils - Heat Transfer Coefficien

Overall Heat Transfer Coefficient - Calculate overall heat transfer coefficients for walls or heat exchangers Steam Condensation and Heat Transfer - Heat transfer when condensing steam Steam Heating Process - Load Calculating - Calculating the amount of steam in non-flow batch and continuous flow heating processes

Get a Quote
openings - u

openings - U

When gases flow along both sides, the overall heat-transfer coefficient is very poor, and the best solution is to make use of heat-pipes as intermediate heat-transfer devices between the gas streams; otherwise, finned separating surfaces, or, better, direct contact

Get a Quote
tank heating using steam co

Tank Heating using Steam Co

Internal Coil area for heating tank contents using condensing steam. CheCalc. Chemical engineering calculations to assist process, plant operation and maintenance engineers. CHECALC CHECALC. ... Overall Heat Transfer Coefficient (U) BTU/h.ft².°F. Heating Time (θ) hr. Result

Get a Quote
overall heat transfer coefficient for tank heaters (steam .

Overall Heat Transfer Coefficient For Tank Heaters (Steam .

Apr 29, 2015· Q = Heat Loss Rate from tank, W or Btu/hr U o = Overall Heat Transfer Coefficient, W / m 2. ⁰C, Btu / hr.ft 2. ⁰F ΔT = Temperature difference between steam supply temperature and bulk process fluid temperature in tank, ⁰C, ⁰F For heat loss rate from storage tanks, refer this very well known post on "Cheresources":

Get a Quote
heating coil in a tank - heat transfer & thermodynamics .

Heating Coil in a tank - Heat Transfer & Thermodynamics .

Jun 04, 2004· As EGT01 suggests, I often resorted to Kern's classical "Process Heat Transfer". However, you are in for some frustration if you are going to dedicate yourself to finding film coefficients. I am going to assume that by "the heat transfer coefficient on the oil side" you mean the Overall Heat Transfer Coefficient, "U".

Get a Quote
heat transfer coefficient - an overview | sciencedirect topi

Heat Transfer Coefficient - an overview | ScienceDirect Topi

The overall heat transfer coefficient (U) depends on individual heat transfer coefficients and the heat resistance offered by the tube-wall. We assume the coolant heat transfer coefficient (h cool) and the tube wall resistance remains constant.The refrigerant heat transfer coefficient (h ref) depends on the heat flux which itself depends on the heat transfer coefficient.

Get a Quote
overall heat transfer coefficient table charts and .

Overall Heat Transfer Coefficient Table Charts and .

Overall Heat Transfer Coefficient Table Chart: The heat transfer coefficient is the proportionality coefficient between the heat flux and the thermodynamic driving force for the flow of heat (i.e., the temperature difference, ΔT): h = q / (Ts - K) where: q: amount of heat required (Heat Flux), W/m2 i.e., thermal power per unit area, q = d\dot ...

Get a Quote