All products of Wuxi ZOZEN Boiler Co., Ltd. are 100% factory inspected to ensure high quality. We have manufactured 6 series of 400 types of boilers, including steam boilers, hot water boilers, power station boilers, fire tube boilers, water tube boilers, CFB boilers, chain grate boilers, biomass fuel boilers, gas and oil boilers and waste heat Recovery boilers, products are widely used in manufacturing (chemical, coking, paper, food processing, etc.), thermal power plants, building materials and other industries.

Recommend Products

gas/oil fired boiler

1-20 t/h | 0.7-2 Mpa

biomass steam boiler

2 – 20 t/h | 1 - 2.5 Mpa

thermal oil heater

700 - 14000 KW

CFB steam boiler

35 - 75 t/h | 1.25 - 5.3 Mpa

Related Cases

Coal-fired Boiler

6tph SZL series boiler project

Location: Bangladesh

Equipment: SZL6-1.25-AII

Coal-fired Boiler

4 tph DZL series boiler Project

Location: Central Java, Indonesia

Equipment: DZL4-1.25-AII

Biomass-fired Boiler

20 tph SZL series boiler project

Location: Thailand

Equipment: SZL20-2.45-M

boiler – fundamentals and best practic

Boiler – Fundamentals and Best Practic

further addition of heat to water at 100°C will not increase the temperature but will convert some of the water into steam In order to convert water into steam 2,257 kJ/kg (971Btu/lb) of additional heat must be added This cannot be detected as a rise in temperature and is called the Latent Heat of Vaporisation (Specific Enthalpy - Evaporation ...

Get a Quote
reasons why the condensate- or boiler-feed pump is .

Reasons why the condensate- or boiler-feed pump is .

Jun 25, 2014· Just make sure the vacuum breaker winds up between the boiler water line and the motorized valves. There's a "master" trap at the inlet to the condensate pump. When steam traps fail in the opened position, the returning condensate eventually will get too hot …

Get a Quote
208v vs. 240v - google grou

208V vs. 240V - Google Grou

Apr 23, 2000· The phase difference between two hot legs on a 3 phase system is 120 degrees. In a single phase system, the two hot legs are 180 degrees out of phase, and if you drew equal current from both legs to neutral, there would be zero net current in the neutral. Using two hot legs of a 3 phase system, with equal

Get a Quote
100% safety phase changing vacuum hot water boil

100% Safety Phase Changing Vacuum Hot Water Boil

Nearly no news reported vacuum hot water boiler explosion event. This is because phase changing vacuum hot water boiler working in the negative pressure, unlike other hot water boiler. This ZWNS series boiler capacity is from 0.5 to 6 ton per hour, basically meet hotels, schools, buildings, supermarkets hot water or heating requirements.

Get a Quote
observing boiler safety rules - idc-online.c

OBSERVING BOILER SAFETY RULES - idc-online.c

Ø Do NOT refill a boiler while it is hot. Treated warm water should be used. The boiler should be vented to permit air to escape. Ø Check the water level in the gauge glass (mid point) and all the gauge glass valves are open. Ø Test true water level by opening the test cocks, starting with the uppermost. Ø Open all the feed water supply valves.

Get a Quote
how to replace a hot water heater relief valv

How to replace a hot water heater relief valv

You need to get the tank 100 percent full before you turn the power on or you may burn the top element on the water heater out. I have seen this happen so many times.

Get a Quote
energy star most efficient 2020 — boilers | products .

ENERGY STAR Most Efficient 2020 — Boilers | Products .

Simultaneous domestic hot water and heating providing superior comfort for both. Scalding Prevention for Domestic Hot Water Safety. Outdoor Temperature Reset Sensor Included. External Pump Terminal Available. PVC, CPVC and PP Venting Capability (2” - up to 60 ft. / 3” - up to 100 …

Get a Quote
boiler shutdown, - banks engineeri

Boiler Shutdown, - Banks Engineeri

When the steam pressure has dropped to approximately 20 psig, open the drum vent valve to prevent a vacuum from forming within the boiler. The boiler is drained only after the water temperature drops below 200°F. To insure that the safety valves are maintained in good working order they can be hand lifted or popped at periodic intervals.

Get a Quote
boiler formulas | johnston boil

Boiler Formulas | Johnston Boil

Factor of Evaporation Water enters the boiler at 225°F. The boiler pressure is 100 psi and the boiler water temperature is 338°F. The latent heat is 881 Btu.

Get a Quote
boiler safety programs & inspection forms - safetyin

Boiler Safety Programs & Inspection Forms - SafetyIn

Many types of boilers that are used in commercial and public facilities that produce steam (either low or high pressure), hot water heating for use in comfort air heating systems, and hot water supply for use in domestic water systems (such as showers, sinks, pools, or for miscellaneous use) which includes potable hot water heater type boilers.

Get a Quote
three common boiler safety devices - facilities management .

Three Common Boiler Safety Devices - Facilities Management .

Aug 16, 2010· Boiler operators and technicians should pay close attention to three key safety devices to protect personnel, equipment, and the facility: Safety valves. The safety valve is the most important safety device in a boiler or domestic hot-water system. It is designed to relieve internal pressure if a range of failures occur within the system.

Get a Quote
vacuum steam boil

vacuum steam boil

Vacuum boiler,Vacuum Hot Water Heating Boiler-Zozen Boiler. Vacuum hot water boiler is an ideal solution for heating supply, gas and oil are available to be used in the heating boiler. There is completely deoxy purified water in the furnace, so there is no corrosion and incrustation. Working in the negative pressure, vacuum hot water boiler …

Get a Quote
when does a water heater become a boiler? | 2016-01-12 .

When does a water heater become a boiler? | 2016-01-12 .

Jan 12, 2016· The first hour rating represents how much hot water the unit can supply in a one-hour period if it starts with a full tank of hot water. For example, in Figure A the Energy Guide Label illustrates a water heater with a first hour rating of 57 gallons (215.77 liters).

Get a Quote
raypak pool & spa, residential and commercial hydronic .

Raypak Pool & Spa, Residential and Commercial Hydronic .

Raypak Pool & Spa, Residential and Commercial Hydronic Products -

Get a Quote
heat pipe - wikiped

Heat pipe - Wikiped

A heat pipe is a heat-transfer device that combines the principles of both thermal conductivity and phase transition to effectively transfer heat between two solid interfaces.. At the hot interface of a heat pipe, a liquid in contact with a thermally conductive solid surface turns into a vapor by absorbing heat from that surface. The vapor then travels along the heat pipe to the cold interface ...

Get a Quote
top ten boiler and combustion safety issues to avo

Top Ten Boiler and Combustion Safety Issues to Avo

One is the boiler /machinery (B/M) coverage for the pressure side, meaning the tubes, drums, water level controls and safety relief valves. The second part of a boiler’s insurance is the property coverage, which covers the fire side, such as the fuel train, firebox, and refractory-related issues.

Get a Quote
vacuum phase change hot water boil

vacuum phase change hot water boil

100% Safety Phase Changing Vacuum Hot Water Boiler. Nearly no news reported vacuum hot water boiler explosion event. This is because phase changing vacuum hot water boiler working in the negative pressure, unlike other hot water boiler. This ZWNS series boiler capacity is from 0.5 to 6 ton per hour, basically meet hotels, schools, buildings ...

Get a Quote
100% safety phase changing vacuum hot water boiler--z

100% Safety Phase Changing Vacuum Hot Water Boiler--Z

This ZWNS series boiler capacity is from 0.5 to 7 MW per hour, basically meet hotels, schools, buildings, supermarkets hot water or heating requirements. 100% Safety Phase Changing Vacuum Hot Water Boiler. Water in vacuum chamber, as a kind of thermal medium, to transfer heat between heat-exchanging tube and heat exchanger. is under whole ...

Get a Quote
nec 2017 code changes chapter 4 - equipment for general u

NEC 2017 Code Changes Chapter 4 - Equipment for General U

(3) Where installed in low-pressure water heater tanks or open-outlet water heater vessels Informational Note: Low-pressure and open-outlet heaters are atmospheric pressure water heaters as defined in IEC 60335-2-21, Household and similar electrical appliances — Safety — Particular requirements for storage water …

Get a Quote
how to clean the inside of your boiler - askmed

How to Clean the Inside of your Boiler - AskmeD

Aug 02, 2012· A boiler is made up of sections (cast iron) with nubs on each side creating a nice cap for the flame/heat to pass through. This heats up the sections and the water inside these sections. As you can see from the above picture, in some cases these sections can get packed solid with soot.

Get a Quote
what size breaker for water heater: everything you need to .

What Size Breaker For Water Heater: Everything You Need To .

Also, in case there are other devices connected to the same circuit as the water heater, it is necessary to add the current draw of those devices into consideration while choosing your breaker. Similarly, you can reduce the 125 percent increase to 100 percent if you plan to use the water heater intermittently.

Get a Quote